Ubiquiti PoE Adapters provide a variety of features to help protect your PoE devices:
- Surge protection
- Clamping protection
- Maximum surge discharge
- Peak pulse current
- AC cable with earth ground
Electrostatic discharge (ESD) is the leading cause for outdoor device failures. You can effectively protect against ESD damage using a grounded Ubiquiti PoE Adapter. TOUGHCableTM. and TOUGHCable Connectors.
Specifications |
Model |
POE-54V-80W |
Dimensions |
123 x 65 x 34 mm (4.84 × 2.56 × 1.34”) |
Weight |
299 g (10.55 oz) |
Output Voltage |
54VDC @ 1.5A |
LAN Activity Indicator |
No |
Gigabit LAN Port |
Yes |
Remote Reset Capability |
No |
Reset Button |
No |
Rated Voltage |
100-240VAC @ 50/60Hz |
Input Current |
0.8A @ 120VAC. 0.4A @ 240VAC |
Inrush Current |
<80A Peak @ 120VAC. <120A Peak @ 230VAC |
Efficiency |
87+% |
Output Ripple |
1% Max. |
Switching Frequency |
100 kHz Max. |
Line Regulation |
≤ 3% |
Load Regulation |
≤ 5% |
2-Pair Powering |
– |
4-Pair Powering |
Pins 1. 2. 4. 5 (+) and Pins 3. 6. 7. 8 (-) |
Operating Temperature |
0 to 40° C (32 to 104° F) |
Storage Temperature |
-30 to 70°C (-22 to 158° F) |
Operating Humidity |
35 to 95% Noncondensing |
AC Connector |
IEC-320 C6 |
Data IN / PoE |
RJ45 Shielded Socket |
Surge Protection |
Difference and Common Mode |
Clamping Protection |
11V Data. 60V Power |
Max. Surge Discharge |
1500A (8/20 μs) Power |
Peak Pulse Current |
36A (10/1000 μs) Data |
Shunt Capacitance |
<5 pF data |
Response Time |
<1 ns |
Certifications |
CE. FCC. IC. UL |